MV Electrical Protection Systems for Industry

Medium-voltage electrical protection systems for industry are essential to ensure the safety, reliability, and continuity of industrial electrical installations.
COL Group designs and manufactures advanced protection solutions capable of detecting and promptly managing anomalies and faults, helping prevent service interruptions and damage to equipment.
Our technologies comply with the highest regulatory standards and integrate seamlessly into industrial power distribution systems.

CU90N

Voltage regulator for transformer with on-load tap changer (ANSI 90)

DIA4L

CEI 0-16 2022-03 for MV self-producers


Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers
Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)
Supports Modbus RTU

DIA4L+

Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers

Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)
Includes auto-reclosing, virtual OR logic, programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

DIA4N

Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers

Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)

IFD4L

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N-59N-50BF-74TCS)
Includes 2nd harmonic restraint, cold load pickup, Modbus RTU

IFD4L+

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N-59N-50BF-74TCS)
Includes 2nd harmonic restraint, cold load pickup, logical selectivity (wired and virtual), programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

IFD4N

General protection relay compliant with CEI 0-16:2022-03

Performs bi-phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N)

IFX3S

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-74TCS)

IFX4L

Svolge funzioni di massima corrente di fase e di terra (ANSI 50-51-50N-51N-50BF-74TCS-64S-64T)
Include ritenuta 2a armonica, avviamento a freddo, Modbus RTU.

IFX4L+

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-50BF-74TCS-64S-64T)
Includes 2nd harmonic restraint, cold load pickup, logical selectivity (wired and virtual), programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

IFX4N

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-64S-64T)

Modem DICOR

Communication and remote control device operating over a GSM network, in accordance with the requirements of Italian Regulatory Authority Resolution 421/2014/R/EEL of August 7, 2014.

Modem Linky FV DIN

Dispositivo di comunicazione e controllo remoto su rete GSM/LTE conforme alla delibera 421/2014/R/EEL del 07/08/2014

DIA4L+

Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers

Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)
Includes auto-reclosing, virtual OR logic, programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

IFD4L+

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N-59N-50BF-74TCS)
Includes 2nd harmonic restraint, cold load pickup, logical selectivity (wired and virtual), programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

IFX4L+

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-50BF-74TCS-64S-64T)
Includes 2nd harmonic restraint, cold load pickup, logical selectivity (wired and virtual), programmable logic (PLC text based), animated synoptic, USB Type-C, Modbus RTU / TCP-IP

DIA4L

CEI 0-16 2022-03 for MV self-producers


Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers
Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)
Supports Modbus RTU

IFD4L

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N-59N-50BF-74TCS)
Includes 2nd harmonic restraint, cold load pickup, Modbus RTU

IFX4L

Svolge funzioni di massima corrente di fase e di terra (ANSI 50-51-50N-51N-50BF-74TCS-64S-64T)
Include ritenuta 2a armonica, avviamento a freddo, Modbus RTU.

PQD4L

Active and reactive power protection relay, directional energy protection (ANSI 32P-37P-32Q-37Q-67)
Includes undervoltage threshold, Modbus RTU

UAR4L

Relè di protezione di tensione linea/terra (ANSI 59-27-59Vo-81-64S), bilancia di tensione (ANSI 60)
Supporta Modbus RTU

CU90N

Voltage regulator for transformer with on-load tap changer (ANSI 90)

DIA4N

Interface protection relay compliant with CEI 0-16:2022-03 for MV self-producers

Performs undervoltage and overvoltage functions (3-phase), residual overvoltage, under and overfrequency, and voltage unblocking (ANSI 27-27V1-59-59Avg-59N-59V2-81-81V-BF)

HAR1N

Frequency protection relay, maximum flux, rate of change of frequency, phase jump (ANSI 81-59/81-dF/dt-dφ)

IAD3N

Directional earth or energy protection relay (ANSI 67-67N-32)

IBF4N

Breaker failure protection relay

IDB4N

Relè di protezione differenziale di sbarra (ANSI 87B).

IDG8N

Selective generator and stator earth differential protection relay (ANSI 87G-64Ss)

IDM8N

Machine differential protection relay specific to Enel DV6903RO – Ed.1 (ANSI 87T)

IDT8N

Transformer and group differential protection relay (ANSI 87T)

IFD4N

General protection relay compliant with CEI 0-16:2022-03

Performs bi-phase and earth overcurrent, directional and non-directional, plus residual overvoltage (ANSI 50-51-50N-51N-67N)

IFF4E

Numerical overcurrent protection unit (RFI 794/612)

IFF4N

Numerical overcurrent protection unit (RFI 794/410 and 794/502)

IFX4N

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-64S-64T)

IFX4NR

Line/earth overcurrent protection relay with auto-recloser (ANSI 50-51-51N-64S-64T-79)

IMT4N

Motor protection relay (ANSI 49-50-51R-46-51N-37-66)

ING4N

Load imbalance, stator overtemperature, phase/earth overcurrent protection relay (ANSI 46-49-50-51-51N)

PQR4N

Field loss, rotor earth fault, directional power (P & Q) protection relay (ANSI 40-64R-32)

SCK4N

Automatic synchronizing device with synchro-check (ANSI 25)

SCK4N-D

Automatic synchronizing device with synchro-check (ANSI 25)

UAR4N

Line-to-ground voltage protection relay (ANSI 59-27-59Vo-64S), voltage balance (ANSI 60)

UHF4N

Voltage and frequency protection relay (ANSI 59-27-59N-81-df/dt)

UHR4N

100% stator earth protection relay (ANSI 64S-100%)

ZFD8N

Directional overcurrent + earth and auto-recloser or low impedance protection relay (ANSI 67-67N-50-51-59Vo-79-21)

ZFP8N

Loss-of-synchronism protection relay (ANSI 78)

IFX3S

General protection relay compliant with CEI 0-16:2022-03

Performs phase and earth overcurrent functions (ANSI 50-51-50N-51N-74TCS)